XLPE Insulated · CWS Screened · SWA / AWA Armoured

Medium Voltage XLPE Cables, 3.6/6–26/35kV

Single-core and three-core MV power cables with copper or aluminium conductors, copper wire screen and optional SWA or AWA armour for direct burial — supplied to utility, renewable energy and industrial projects to IEC 60502-2 and BS 6622.
XLPE insulated

Medium-voltage XLPE-insulated cables carry power in transmission and distribution networks at AC rated voltages from 3.6/6kV up to 26/35kV, manufactured to IEC 60502-2 and BS 6622.

From the inside out, an MV cable combines a stranded conductor, conductor screen, XLPE insulation, insulation screen, metallic (copper wire) screen, binder, optional armour and an outer sheath — each layer matched to the voltage, installation environment and required standard.

Medium Voltage Cable Catalouge

ZMS provides our partners around the world with brochures of our cable products, including aerial cables, submarine cables, control cables and other types of special cables, and more.

Single-Core and Three-Core MV XLPE Cables

Choose the core arrangement by circuit layout, conductor size and installation method. Both configurations can be supplied with copper or aluminium conductors and optional armour.

Single-core medium-voltage power cable structure and technical parameters introduction

1 CORE · SINGLE-CABLE CIRCUIT

Single-Core (1C) MV Cable

One conductor per cable; three single-core cables are laid together to form a three-phase circuit. Preferred from 95mm² upward for better flexibility and easier pulling through ducts and trenches.

Sections: 25–630 mm²

Typical use: Substations, urban grid upgrades, large industrial sites

Standard: IEC 60502-2, BS 6622

Note: Single-core AC circuits use AWA armour to avoid magnetic losses

ABC of Pressure Bundled Cables in Overheads

3 CORE · SINGLE CABLE THREE-PHASE

Three-Core (3C) MV Cable

Three cores assembled in one cable for compact three-phase circuits, suited to distribution networks, indoor and outdoor installation, buried and underwater routes, industrial plants and distribution stations.

Voltage: 3.8/6.6 – 19/33 kV

Sections: 25–630 mm²

Standard: IEC 60502, BS 7870, GB/T 12706

Packing: Iron drum or wooden drum

MV Cable Specification Overview

Rated voltage, conductor range, screen and armour options aligned to the relevant national and international standards. Type-test reports and third-party inspection can be provided on request.

TypeCoresConductorRated voltageScreenArmourStandards
1C MV XLPE1Cu / Al, 25–630 mm²3.6/6 – 26/35 kVCopper wire screen (CWS)AWA optionalIEC 60502-2, BS 6622
3C MV XLPE3Cu / Al, 25–630 mm²3.8/6.6 – 19/33 kVCopper wire screen (CWS)SWA / AWA optionalIEC 60502, BS 7870, GB/T 12706

Available conductor and sheath materials, LSZH / flame-retardant options and special armour configurations are quoted per project specification.

Applications Across Grid, Energy and Industry

MV XLPE cables are selected for the voltage level, installation environment and protection requirements of each project. The recommended cable type for each scenario is listed below.

medium voltage cable industry applications

Power Utilities

Urban and rural distribution networks, substations, overhead-to-underground upgrades and grid expansion.

Recommended: XLPE MV, armoured MV, 1C & 3C (11 / 15 / 22 / 33 kV)

Renewable Energy

Solar and wind farms, battery energy storage systems and grid connection lines.

Recommended: XLPE MV, CWS cable, LSZH MV, armoured MV

Mining

Underground and open-pit mines, crushers, conveyors, pumps and mine substations.

Recommended: SWA MV, STA MV, heavy-duty XLPE

Oil, Gas & Petrochemical

Refineries, offshore platforms, LNG terminals, petrochemical plants and hazardous areas.

Recommended: Flame-retardant MV, LSZH, armoured, corrosion-resistant

Industrial Manufacturing

Steel mills, cement, chemical and paper plants, automotive lines and heavy machinery.

Recommended: XLPE MV, armoured, flexible industrial MV

Infrastructure & Commercial

Airports, railways, metro and tunnels, hospitals, data centres and large building complexes.

Recommended: LSZH, fire-resistant, armoured, XLPE MV

From Conductor Drawing to Shipment

A controlled nine-step production line covers conductor preparation, insulation, cabling, armour, sheathing, testing and packing, with routine and type testing before release.

Wire Drawing

Copper or aluminium rods drawn to the required conductor gauge.

Bare Conductor Stranding

Wires stranded and compacted into the finished conductor.

Extrusion Insulation

Conductor screen, XLPE insulation and insulation screen extruded in line.

Cabling

Cores laid up, filled and bound into the cable assembly.

Armour

SWA or AWA armour applied where mechanical protection is required.

Extruded Sheath

PVC / PE / LSZH outer sheath extruded and marked.

Packing

Cables laid on wooden or iron drums, sealed and protected.

Testing

Electrical, dimensional and routine tests passed before release.

Loading

Drums packed for FCL or LCL shipment to the destination port.

MV Cable Projects Delivered Overseas

Representative supply cases for distribution and renewable projects, with the rated standard, cable construction, delivery time and warranty retained for reference.

ZMS partners with South Africa on medium voltage cables

6.35/11 kV SABS 1339 Distribution Cable

  • StandardSABS 1339, 6.35/11 kV
  • Construction3-core Cu XLPE PVC SWA PVC(FR)
  • Sizes240 mm²×3C · 150 mm²×3C · 70 mm²×3C
Lead time 60 daysWarranty 18 months South Africa

YJLV32 3×185 19/33 kV Power Cable

  • TypeYJLV32, 3-core aluminium, 19/33 kV
  • Conductor3 × 185 mm²
  • Quantity24,000 m total
  • QualificationISO / IEC aligned production and testing

Lead time 45 daysWarranty 18 months Iceland

Selection, Certification, Delivery and Packaging

End-to-end support from cable selection and specification to documentation, shipment and after-sales follow-up.

High Voltage DC Cable

Product Selection Service

ZMS offers a comprehensive range of cable and conductor products. Our engineers help you select the right cable type, size and standard for your specific project requirements.

Professional certification quality assurance

Quality Certification Service

All ZMS cables are manufactured and tested according to GB, IEC, BS, NFC, ASTM and DIN standards. Full type-test reports and third-party inspection certificates are available on request.

ZMS cable factory

Professional Customer Service

Our technical team provides free consulting and one-stop project support, from cable selection and quotation to delivery tracking and after-sales service, with 24-hour response.

delivery and shipping service

Delivery and Shipping Service

We provide reliable worldwide shipping with secure packaging. Standard cables are ready within 7–15 days, with full container or LCL options to reduce your logistics costs.

cable levels

Packaging Service

Cables are packed on wooden reels, corrugated boxes or coils. Cable ends are sealed with BOPP tape and non-hygroscopic caps. Custom shipping marks and labeling are available on request.

Reasons to Source MV Cables From ZMS

Engineering-led selection, documented quality and reliable export delivery for grid and industrial MV projects.

Engineering Selection Support

Core arrangement, conductor material, screen and armour matched to your installation route, voltage level and applicable standard.

Certification & Test Reports

ISO 9001 / ISO 14001 quality system, aligned to GB, IEC, BS, NFC, ASTM and DIN; routine and type-test documentation available on request.

Custom Cable Design

Special conductor sizes, LSZH or flame-retardant sheath, armour construction and cable marking configured to the project specification.

Global Export Delivery

FCL and LCL shipment, protected drum packing and export documentation prepared for overseas customs clearance.

Common Questions About MV Cables

What voltage range do your MV cables cover?

Single-core cables are offered from 3.6/6 to 26/35 kV; three-core cables cover 3.8/6.6–19/33 kV, including 3.6/6, 6/10, 8.7/15, 12/20, 18/30 and 26/35 kV ratings. Confirm the rated voltage and installation standard on enquiry so the correct construction can be quoted.

Should I choose single-core or three-core MV cable?

Three-core cable forms a three-phase circuit in one cable and suits compact distribution routes. Single-core cable uses three separate cables and is preferred from 95mm² upward where flexibility and duct pulling matter. In AC circuits, single-core cables use AWA armour to avoid magnetic losses.

What conductor materials and sizes are available?

Copper or aluminium conductors are available from 25 to 630 mm². Special sizes, sectional combinations and shielding or armour options can be reviewed against your project specification.

Can you provide type-test reports and third-party inspection?

Yes. Type-test reports, routine test records and arrangements for third-party inspection can be provided together with the order, where required by the project specification or local authority.